ABSTRACT
Objective To study the feasibility of applying electronic cleaning to intestinal contents tagging by diatrizoate meglumine for single-source dual-energy CT colonography with sequential acquisitions and volume scanning.Methods Twenty-four volunteers had fine effect of intestinal contents tagging by diatrizoate meglumine,good colorectal distension effect,fine image quality of dual-energy fusion colorectal images,and with informed consents were enrolled in this study.The single-source dual-energy CT colonography with sequential acquisitions and volume scanning was performed with an Acquilion ONE 320 row CT scanner,tube voltage 135 kVp/80 kVp.The intestinal contents conducted the dual-energy electronic cleaned based on decomposition of intestinal contents tagging by diatrizoate meglumine,soft tissue and air.The intestinal contents in one segment of intestinal lumen being 100% electronically cleaned served as the basic standard,the electronic cleaning effects were divided into the 5 grades:excellent,good,moderate,fair and poor;and grade 1-3 were effective fecal electronic cleaning.Results The grade 1,2,3,4,5 of electronic cleaning effect for solid as the main intestinal contents were 22.2%,53.3%,17.8%,6.7% and 0% respectively;and which of electronic cleaning effect for liquid as the main intestinal contents were 47.5%,47.5%,5.0%,0% and 0% respectively.The together total effective electronic cleaning of intestinal contents was 97.9% and the electronic cleaning effect was good.Conclusion Electronic cleaning could be used in the intestinal contents tagging by diatrizoate meglumine for single-source dual-energy CT colonography with sequential acquisitions and volume scanning.
ABSTRACT
Objective To study the compliance of examinees,and effectiveness of colorectal distension with partially automated and individualized insufflation of air for dual-energy CT colonography.Methods Forty-six healthy adult volunteers without history of conditions affecting gastrointestinal motor function were enrolled in this study.One day before CT examination,volunteers were asked to orally administered 60 mL 4% diatrizoate meglumine five times for fecal tagging.Air was insufflated by using an inflator in a partially automated and individualized manner.The volunteers were initially asked to assume the right lateral decubitus position,then slowly turn to the supine position.Insufflation rate began at 1.5 L/min,and decreased to 0.5 L/min at later stage.The necessity and volume of air insufflation were decided according to effectiveness of colorectal distension on CT scout images,self-reported sensation of volunteers,and intestinal pressure.Dual-energy CT scanning was performed,and dual-energy blended images were acquired.Compliance of volunteers was statistically analyzed.The effectiveness of colorectal segments distension was statistically analyzed by using Kruskal-Wallis H test.Results No abdominal pain,bloating,nausea or vomiting were noted in the 46 volunteers.All volunteers easily accepted colorectal insufflation of air,with grade 1 compliance.The effectiveness of colorectal distension of grades 1,2,3 and 4 were 0%,2.1%,5.1% and 92.8%,respectively.The difference of effectiveness of colorectal segments distension had no statistical significance(χ2=6.19,P=0.288).The effectiveness of insufflation was poor in 6 colorectal segments,including 2 in sigmoid colon and 2 in rectum.Effectiveness of insufflation was suboptimal in 14 colorectal segments,including 4 in descending colon,4 in sigmoid colon,and 3 in rectum.Conclusion Compliance of examinees with partially automated and individualized insufflation of air for dual-energy CT colonography is excellent,with good effectiveness of colorectal distension.